About this product
White CH2 push-type spring wire connector
RS5670 is a white CH2 two-position wire connector with spring-release tabs. It provides a screwless way to make a removable wire connection: press the appropriate tab, insert the prepared conductor and release the tab to clamp it. The product photos show the insulated body, release tabs and wire-entry openings. This listing supplies one connector, not a bag or multipack.
Connector details
Connector style: CH2 push-type spring clamp.
Body colour: white.
Configuration: two-position connector.
Existing listed voltage limit: 250V.
Existing listed current limit: 10A.
Package: 1 x CH2 wire connector, SKU RS5670.
The voltage and current above are the existing listing's stated limits, not proof of independent certification or suitability for every installation. Actual use depends on conductor size, termination quality, temperature, enclosure and applicable electrical requirements. This listing does not establish a verified wire-gauge range, temperature rating, flame classification or water-protection rating. Do not assume a similar-looking CH2 connector has identical specifications.
Prepare and connect with power off
Isolate the circuit and verify it is de-energised before inserting or removing wires. Inspect the connector for cracks or damaged clamps. Use a conductor type and size confirmed suitable for the actual terminal. Strip only enough insulation for the conductor to seat fully inside the contact, without exposed copper outside the housing.
Press the release tab, insert the conductor into its wire-entry opening, then release the tab. Keep all strands inside the terminal. The clamp must grip conductor rather than insulation. Gently pull-test each wire and redo any loose connection. Provide suitable cable strain relief; the connector is not a support for hanging cables.
Confirm the electrical paths
With the connector disconnected and unpowered, use a continuity meter to confirm which entry points share a terminal and that separate terminals remain isolated. Never connect opposite supply conductors to a common conductive path. Check the circuit before restoring power.
For bench wiring or lighting projects, choose the connector only after confirming the actual load and installation requirements. Mains wiring requires suitable verified components, proper enclosure and a qualified person. Do not treat the white housing as proof of shock protection, outdoor sealing or fireproof construction. Wires, enclosure, tools and power supply are not included.