About this product
Four-channel relay module with 12V relay coils
NA191 is a four-channel electromechanical relay board with optocouplers, status indicators and screw-terminal load connections. The photographed relay cases are marked SRD-12VDC-SL-C, identifying the 12V coil version. Each relay provides a separate changeover contact set for a compatible switching project.
Identify the supplied board
Channels: four independently controlled relays.
Relay coil version shown: 12V DC.
Control header labels: GND, IN1, IN2, IN3, IN4 and VCC.
Additional supply header: JD-VCC, VCC and GND, with a fitted jumper.
Output: one common, normally-open and normally-closed contact set per channel.
The JD-VCC jumper is associated with the relay supply arrangement. It is not the HIGH/LOW trigger selector found on some other relay modules. Before connecting power, confirm the supplied board's circuit, jumper position and the required voltages on the logic and relay sides. Never connect a 12V supply directly to a microcontroller GPIO.
Control and initial testing
IN1 to IN4 control the respective channels. Verify the required trigger polarity and input current for the supplied board rather than relying on the contradictory generic trigger descriptions used for similar modules. Direct compatibility with every Arduino, ESP32, Raspberry Pi or PLC output is not guaranteed. Use an appropriate interface where voltage or drive requirements differ.
Start with one channel and a safe low-voltage DC test load. Check the controller's output during boot, reset and disconnection. With power off, identify the output contacts from board markings or a continuity test: NC connects to COM when the relay is not energised; NO connects to COM when it operates. Relay contacts switch an external circuit and do not supply power to the load.
Load limits and installation
Relay-case contact markings describe the relay component, not a certified continuous-current rating for the complete board, screw terminals or wiring. Four relays do not establish a combined 40A board capacity. Allow for load startup current, suitable fusing, wire size and suppression for inductive loads.
Optocouplers and PCB spacing do not by themselves establish complete galvanic isolation or safety certification. This exposed board is not a touch-safe mains assembly. Mains installation requires a qualified person, a suitable enclosure and compliant wiring.
Includes one 12V four-channel relay module. Controller, power supply, load, enclosure and connection leads are not included. SKU: NA191.