About this product
DRV8825 bipolar stepper driver with heat sink
RS400 is a compact DRV8825 stepper motor driver carrier supplied with a small heat sink. It controls one suitably connected bipolar stepper motor through STEP and DIR signals from a controller. The product photos show the purple carrier, adjustment trimmer, installed header pins and a separate heat sink. Motor, controller, power supply and wiring are not included.
Control and microstepping
The DRV8825 uses two H-bridges to drive the motor windings and includes current regulation and a microstepping indexer. It supports full-step, half-step, quarter-step, eighth-step, sixteenth-step and thirty-second-step operation. Configure the mode inputs using the DRV8825 truth table and your controller settings. A higher microstep setting changes the required pulse count; it does not guarantee higher positioning accuracy under every load.
Driver type: DRV8825 carrier for one bipolar stepper motor.
Control interface: STEP and DIR.
Microstep modes: full step through 1/32 step.
Current adjustment: onboard trimmer; setup required before use.
Included: one driver module and one small heat sink.
Power and current setup
The DRV8825 IC has an 8.2V to 45V motor-supply operating range. That is an IC specification, not a promise that this carrier can run at every voltage and load combination. Check the actual carrier components, observe supply polarity and allow margin for transients. Use suitable local decoupling and a bulk capacitor close to VMOT and GND. Long power leads can create damaging voltage spikes.
Set the coil-current limit to suit the motor rating, the actual sense-resistor value and available cooling. Do not copy a VREF setting from a different board. Power-supply current is not the same as motor-coil current. This listing does not promise a continuous 2.5A output or a verified PCB layer count. A heat sink alone does not establish a safe current rating.
Connect and test safely
Identify each motor coil pair and read the actual board labels before wiring. Check VMOT, GND, coil outputs, STEP, DIR, mode, enable, reset and sleep connections. Reset and sleep must be high for normal operation. Do not assume every A4988 installation is a direct swap; pin functions and pulse timing differ.
Disconnect all power before changing wiring, inserting the carrier or connecting the motor. Never unplug a stepper motor while the driver is powered. Begin with a conservative current limit and confirm direction, cooling and reliable stepping before increasing load. The driver and motor can become hot during use.